Live object
This lane compares the canonical hydrostatic-equilibrium equation with the same equation after a three-dimensional orthogonal redistribution is inserted only into the reconstructed dark-halo density.
It corrects the earlier off-object failure mode in which a projected proxy or response-space transformation could be mistaken for a direct equation insertion.
Baseline equation
The electron-pressure hydrostatic equation is
The published X-COP hydrostatic NFW profile is the baseline gravitating mass.
Orthogonal-augmented equation
The dark-halo component is reconstructed as
The normalized three-dimensional Plummer kernel acts on this component only:
Equivalently, the mass correction is
and the scored augmented equation is
Gas, stars, electron-density data, and the pressure score are unchanged.
f=0 recovers the baseline exactly.
Source and eligibility
- Dataset: official X-COP public profile release.
- Release page: https://dominiqueeckert.wixsite.com/xcop/data
- Hydrostatic-mass paper: https://doi.org/10.1051/0004-6361/201833323
- Profile archive: https://drive.switch.ch/index.php/s/j3WUOYXWgv9Jbnz/download
- Archive SHA-256:
0edf5038b419b70d070b73b22f4801e27f318b0854db61eec52142c27c140d94
Seven clusters contain every component required by the frozen reconstruction: X-ray pressure, electron density, hydrostatic NFW mass, gas-mass profile, and stellar-mass profile.
The fixed component-validity window is
0.005 <= r/R500 <= 3.0. The first preflight attempt stopped before producing
scores when extrapolated baryonic subtraction became nonphysical beyond this
shared support window. The repaired window was fixed across all eligible
clusters before development optimization; no equation, kernel, sample,
parameter grid, score, or matched control was changed.
Development and heldout lock
The deterministic name-hash split is:
- Development: A2319, A85, ZW1215, A2142.
- Heldout: A644, A2029, A1795.
- Overlap: 0.
- Sample identity SHA-256:
8285acec7f246c2681deaaae007eb3f9f4e94cef33892d3fdd14e01171bd2538.
The shared development grid was:
f in {0, .05, .10, .20, .30, .40, .50, .60, .75, 1.0}d/R500 in {.005, .01, .02, .04, .08, .16}
The selected policy was f=1.0, d=0.01 R500. The fraction reached the
declared upper grid boundary. The grid was not widened after heldout scoring.
The public source was accessible during development. “Heldout” means no heldout baseline or candidate score was executed before the shared policy was frozen; it does not imply secret data.
Score
The score is diagonal X-COP X-ray electron-pressure chi-square. A single additive pressure-boundary nuisance is profiled analytically with the same budget in both arms.
Heldout result
| Cluster | Points | Baseline chi-square | Augmented chi-square | Raw delta | Residual reduction |
|---|---|---|---|---|---|
| A644 | 12 | 46.162435 | 42.699543 | -3.462892 | 7.5015% |
| A2029 | 14 | 58.109244 | 58.053889 | -0.055354 | 0.0953% |
| A1795 | 13 | 40.823629 | 39.984353 | -0.839276 | 2.0559% |
| Total | 39 | 145.095308 | 140.737785 | -4.357523 | 3.0032% |
All three heldout clusters moved in the favorable direction. There was no heldout row fallback and no heldout downlift.
Matched generic controls
At the same frozen f and a half-mass-matched three-dimensional scale:
| Kernel | Augmented chi-square | Raw delta | Residual reduction | Improved |
|---|---|---|---|---|
| Plummer | 140.737785 | -4.357523 | 3.0032% | 3/3 |
| Gaussian | 142.042268 | -3.053040 | 2.1042% | 3/3 |
| Top-hat | 142.806793 | -2.288515 | 1.5773% | 3/3 |
Plummer is strongest in aggregate under this frozen comparison, but every generic smoother also improves all three clusters. The result therefore does not establish unique Plummer physics.
The aggregate ordering is not a per-cluster specificity result. Plummer beat
both matched controls on only 1/3 clusters. A644 supplied 144.57% of the total
Plummer-over-Gaussian aggregate advantage, while A2029 and A1795 net favored
Gaussian. The selected f=1.0 is the full-smoothed-profile replacement
endpoint, not the legacy partial f=0.30 mixture. The deterministic
recomputation is in
aggregate_specificity_audit.json.
Verification
- Direct formal-equation insertion: PASS.
- Dark-halo-only object lock: PASS.
- True three-dimensional Plummer kernel: PASS.
- Exact
f=0mass and pressure-prediction recovery: PASS. - Corrected mass conservation: PASS.
- No heldout row fallback: PASS.
- Deterministic byte-identical replay: PASS.
- R2 source-authority pre-gate: PASS.
- Executed-source post-gate: PASS.
- Internal arithmetic self-audit: PASS.
- Internal execution-path adversarial self-audit: PASS.
- Independent external audit: not established in the stored result artifacts.
Evidence and claim boundary
The X-COP hydrostatic NFW mass profiles were reconstructed from the same thermodynamic profile family used in the pressure consistency score. This is therefore a public-profile direct-equation diagnostic, not an independent raw observational likelihood.
Supported:
On three untouched X-COP cluster profiles, the development-frozen direct halo-only orthogonal insertion moved hydrostatic pressure chi-square from 145.0953 to 140.7378 (delta -4.3575; 3.00% residual reduction), with negative delta in 3/3 clusters and no heldout downlift.
Not supported:
- detection of a new source or physical law;
- proof that the term is required by the data;
- unique validation of Plummer geometry;
- independent raw-observational proof;
- a universal no-downlift guarantee.
Reproduction
See scripts/xcop_hse/README.md. Machine-readable
contracts, policy, rows, controls, and audit receipts are under
results/.